Skip to main content

Nguyen household, Alice Springs: specialist findings

Release B for the Alice Springs home: what a twelve-month measurement year found, the specialists' implications, and the data as CSV. Synthetic case data, handed over in week 7.

Synthetic case data. This is a generated measurement year, produced by the course's model to be consistent with the Alice Springs home. It is not a measurement and no instrument recorded it. It stands in for the year the story says passed between week 7 and Assignment 2, and it is identical for every student who took this home, whatever their Assignment 1said.

Memo

Common Ground Engineering, specialist team, 2028-04-14 · measurement year April 2027 to March 2028

The specialists report conditions and what follows from them. They do not choose the system. That is your recommendation to make inAssignment 2.

What the year found

Rain at the site297 mmlong-term mean 284 mm
Roof inflow to storage21.3 kL98 m² connected at a runoff coefficient of 0.8
Overflow0 kL12 months with storage empty at month end
Indoor use218.9 kL150 L per person per day
Water imported140.2 kLplus 99.6 kL drawn from the bore
Garden water applied42.6 kLestimated unmet demand 99.6 kL
Pump energy228 kWhelectricity at $0.33 per kWh
Harvest weighed44 kgfood waste 7.2 kg/week, 373 kg/year, 61 % plant-based
Peak simultaneous flow21.5 L/min70th percentile event 18 L/min; static lift 2.1 m
Frost nights13air temperature below 0 °C
synthetic dataAnnual totals for the measured year, April 2027 to March 2028. Synthetic case data.

The measured year, month by month

An extract. The full table, with every fixture group, the bore, overflow and the quality flags, is in SYNTHETIC-monthly.csv below.

MonthRain (mm)ETo (mm)Roof in (kL)Tank end (kL)Indoor use (kL)Imported (kL)Garden applied (kL)
Apr 202732.21282.4017.810.13
May 202731.5902.3017.79.12
Jun 202716.6711.1016.79.11.8
Jul 202710.8720.7017.310.11.8
Aug 202714.51011017.710.92.6
Sep 202781380.5017.812.53.5
Oct 202721.21851.501913.84.6
Nov 202723.61981.7018.913.84.9
Dec 202728.92062.1018.613.25
Jan 202835.32202.6020.114.45.3
Feb 202856.21784.20189.23.8
Mar 202817.81681.2019.3144.3
synthetic dataMonthly extract, April 2027 to March 2028. Synthetic case data; ETo is derived from the logged temperatures, not measured.

Growing zones

ZoneArea (m²)TexturepHOrganic C (%)Rooting (cm)Sun, summer / winter (h)ClassNote
G1 Shade-house garden54sandy loam7.90.96012 / 8.5Ashadecloth transmits about 45 per cent of light after ten years
G2 Main garden168loamy sand8.20.68013 / 9Bcalcium carbonate at depth; emitters scaled
G3 Windbreak strip90loamy sand8.30.78010 / 6.5Dtree roots; wind-exposed edge
G4 Trial plot96sand8.40.39013.5 / 9.5Cbare; surface temperature above 60 degC in January
synthetic dataSoil and shade by zone. Laboratory values are synthetic case data; the productivity class is the specialists' judgement from them.

Water quality

MonthSourceTurbidity (NTU)E. coli (MPN/100 mL)Hardness (mg/L CaCO₃)pHNote
2027-04tank T11.832107.8tank holds mixed rain and bore water
2027-10bore0.403857.6hardness and iron explain the emitter scale
2028-01tank T14.9181507.6after the January storm
2028-02bore0.503927.6
2028-02drip emitter depositwhite scale, effervesces in acid: calcium carbonate
synthetic dataSamples taken across the year, including at least one after heavy rain. Synthetic case data.

Hydraulics

Tank outlet at RL 100.25 m; highest fixture is the ensuite shower rose at RL 102.35 m, giving a static lift of 2.1 m. Currently served: whole house and drip, through the existing pressure pump.

Existing pump cuts in at 20 m and out at 34 m of head; the drip zones run off the same pump.

FixtureFlow (L/min)
shower9.1
ensuite shower8.4
basin5.2
kitchen tap7.4
toilet cistern refill7
washing machine fill11.5
drip zone (shade house)6.2
drip zone (fruit block)7.8
synthetic dataMeasured fixture flow rates, used with the flow-event table to size any pump.

What it costs the household now

What the specialists conclude

  1. Emitter blockage is calcium carbonate scale from hard bore water, not biofilm; the fix is filtration and flushing, not new lines.
  2. Carted water arrived in 12 loads of 12 kL, mostly between October and March. The bore allocation was fully used, evenly across months, because the bore pump tops up the tank whenever there is room.
  3. Only one of the five guttered roof zones is connected; the other four together are about twice its area.
  4. The tap timer gave the shade-house vegetables and fruit block about 30 per cent of the irrigation they needed; from December to February the tank was usually empty by mid-morning.

What they could not settle

Gaps in the record

A gap is marked as a gap. Interpolated values are flagged in thequality_flag column of the monthly CSV, and anything you conclude from those months should carry the same flag.

Download the findings

Every file's first line says what it is. The data dictionary gives each column its unit, meaning and kind — synthetic measured year, derived,calendar or sourced. Keep those apart in your own workbook.

FileWhat is in itSizeBasis
SYNTHETIC-monthly.csvThe measured year, month by month: rain, temperature, roof inflow, tank level, indoor use by fixture group, imports, garden application, pump energy, frost12 rowssynthetic case data
SYNTHETIC-zones.csvSoil and shade by growing zone: texture, pH, EC, organic carbon, nutrients, rooting depth, summer and winter sun, relative productivity4 rowssynthetic case data
SYNTHETIC-water-quality.csvWater-quality samples: turbidity, E. coli, hardness, TDS, pH, iron, with the sampling note5 rowssynthetic case data
SYNTHETIC-flow-events.csvThe ten largest simultaneous-draw events: fixtures involved, peak flow and duration10 rowssynthetic case data
SYNTHETIC-food-waste-audit.csvFour one-week kitchen and garden waste audits, split into plant, meat and dairy, and garden4 rowssynthetic case data
BOM-long-term-015590.csvLong-term climate statistics for Bureau of Meteorology station 015590, all years of record12 rowssourced